Friedrich 2009 Air Conditioner User Manual


 
ELECTRONIC CONTROL PANEL
CHECKING ROOM TEMPERATURE
1. Check the room temperature at the electronic control
pad by pressing at the same time, the Fan Speed
button and the Temp/Hour button on the WS/WE/
WY models (see gures 5 and 6).
2. The indoor temperature will display for 10 seconds.
Indoor temperature can be viewed in all modes, including
the Test Mode. The display can be changed back to
the SET temperature by pressing any key (except the
Power (on/off button) or it can do so automatically after
10 seconds have elapsed.
ACTIVATING TEST MODE
Activate Test Mode by pressing at the same time, the Mode
button and the Temp/Hour button on on the WS/WE/
WY models (see gures 5 and 6).
The LEDs for Set/Hour: “Start Time” and “Stop Time” will
blink 1 bps while Test Mode is active.
Test Mode has a duration of 90 minutes. Test Mode can be
activated under any function, including Off.
Test Mode is cancelled by pressing the Power (on/off)
button, unplugging the unit, or when the 90 minutes times
out.
Test Mode settings are factory default of:
Unit operation On, MoneySaver On, Cool Mode, 60
degrees F, speed fan on High. “Timer” and “Set Hour”
features are non-functional.
Test Mode overrides the three minute compressor Lock-
out, all delays for fan motor start, speed change, and when
switching modes.
TESTING THE ELECTRONIC CONTROL
Figure 5: “WS” Cooling only models
Electronic Control Panel
Temp/Hour
Cool
Money Saver
®
Fan Only
Clock
Start Time
Stop Time
Power
Fan
Speed
Mode
PM
Timer
On/Off
Set
Hour
72
Figure 6: “WE”/”WY” heat/cool models
Electronic Control Panel
Error Code Mode is used to display all error codes
stored since reset. It is a sub-mode of Test Mode. Unit
must be in Test Mode to enter the Error Code function.
Activating Error Code Mode: Press the TIMER On/
Off” button on the WS/WE/WY models (see gures 5
and 6). The LED for the TIMER On/Off will ash 1 bps
(beats per second) while Error Code Mode is active.
Pressing the Temp/Hour button will display “00”.
Consecutive presses will scroll through all error codes
stored. Press the Temp/Hour button to see the
reverse order of the error codes. When the end of the
stored error codes is reached the temperature Set Point
will appear. (Each error code is listed once)
Exiting Error Code Mode: press the Timer On/Off
button.
Clearing Error Codes: Error codes are cleared
from the memory by exiting from Error Code Mode.
MEMORY: On WS/WE/WY
The electronic control has a memory to retain all
functions and settings, as set up by the user, in the event
of a power failure. For example: once power is restored
to the unit, there is a two second delay before the fan
comes on and approximately three minutes delay before
the compressor is activated providing that the mode was
set for cooling and the set point temperature has not
been met in the room.
ERROR CODE MODE
12