Note: If adding the G8007 series brick liner
accessory, install it now. Follow instructions
in G8007 accessory kit.
CAUTION: Do not pick up
log base assembly by burner.
This could damage burner. Only
handle base by grates.
3. Route gas line (provided by installer)
from equipment shutoff valve to replace.
Route exible gas supply line through one
of the access holes.
NOTICE: Most building codes
do not permit concealed gas
connections. A exible gas line
is provided to allow accessibility
from the replace (see Figure 17).
The exible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
4. Attach exible gas line to gas supply (see
Figure 17). Check tightness of exible gas
line attached to gas regulator of replace
(see Figure 17).
5. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
6. Replace log base assembly back into
replace. Feed exible gas line into re-
place base area while replacing log base
assembly. Make sure the entire exible
gas line is in replace base area. Reat-
tach log base assembly to replace with
screws removed in step 2.
INSTALLATION
Continued
Figure 16 - Removing Log Base
Assembly From Fireplace
Figure 17 - Attaching Flexible Gas Lines
Together
Flexible Gas Line
from Fireplace
Gas Regulator
To Fireplace
Gas Regulator
Equipment
Shutoff Valve
Provided by
Installer
Propane/LP
To External
Regulator
Natural Gas
To Gas Meter
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
We recommend that you install a sediment
trap in supply line as shown in Figure 15,
page 14. Locate sediment trap where it is
within reach for cleaning. Install in piping
system between fuel supply and replace.
Locate sediment trap where trapped matter
is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them
from going into replace gas controls. If sedi-
ment trap is not installed or is installed wrong,
replace may not run properly.
CONNECTING FIREPLACE TO GAS
SUPPLY
Installation Items Needed
5/16" hex socket wrench or nut-driver
Phillips screwdriver
sealant (resistant to propane/LP gas, not
provided)
1. Remove replace screen. Remove one
screw that holds replace screen in place
for shipping. This screw is located near
top left side of screen. Discard screw.
Lift replace screen up and pull out to
remove.
2. Remove screws that attach log base
assembly to replace (see Figure 16).
Carefully lift up log base assembly and
remove from replace (see Figure 16).