FMI VSGF36NRC Indoor Fireplace User Manual


 
www.fmiproducts.com
121082-01K
30
SPECIFICATIONS
Figure 47 - Remote Control Wiring Diagram
Black Connectors
Receiver
To Thermopile
White
Red
Model VSGF36NRC
Rating (Variable): 33,000/21,500 Btu/Hr
Type Gas: Natural Gas
Ignition: Electronic
Pressure Manifold: 3.5" W.C.
Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
Shipping Weight: 120 lbs.
* For input adjustment
Model VSGF36PRC
Rating (Variable): 33,000/21,500 Btu/Hr
Type Gas: Propane/LP
Ignition: Electronic
Pressure Manifold: 7.9" W.C.
Inlet Gas Pressure (in. of water):
Maximum 13" W.C. Minimum* 11" W.C.
Shipping Weight: 120 lbs.
* For input adjustment
TECHNICAL SERVICE
You may have further questions about installa-
tion, operation or troubleshooting. If so, contact
FMI PRODUCTS, LLC at 1-866-328-4537.
When calling, please have your model and
serial numbers of your rebox ready.
You can also visit FMI PRODUCTS, LLC’s
web site at www.fmiproducts.com.
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specied heat
propane/LP gas supply may be low for
propane/LP unit
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
WIRING DIAGRAM
Note: For proper operation of remote control, wires from thermopile to control receiver must
be connected exactly as shown.