OPTIONAL OUTSIDE AIR KIT
(MODEL AK4)
The installation of an outside air kit should be
completed during the rough framing of the re-
place due to the nature of it's location. Outside
combustion air is accessed through a vented
crawl space.
CAUTION: Air inlet ducts
must not be terminated in an
attic space.
Avoid installing outside air eyebrow in areas where
inlet opening may be blocked by snow, bushes or
other obstacles (see Figure 10).
The maximum height for the air inlet termination
cannot exceed 3 feet below the B-vent termination
exhaust height.
Figure 10 - Outside Air Kit
Secure to Collars with Duct Tape or
Screws
Air Inlet
Location
Must Allow
For Bushes
or Snow
Vent Hood
Required for
Wall Installation
Air Inlet
Eyebrow
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
MILLIVOLT MODELS (GL36PN/PNP
AND VGL36PN/PNP)
The installation of a wall switch in this millivolt
control appliance allows you to activate the gas
control valve without the use of normal current.
CAUTION: Do not connect
thismillivoltsystemwallswitch
toaregular120vpowersource!
Gasvalvewillbedamagedbe-
yond repair.
WallSwitchInstallation
1. Remove the J-box cover plate from side of
appliance’s outer surround.
2. Using the 18 ga. millivolt wire and wall switch
(both supplied), connect wiring per wiring
diagram (see Figure 11). For more detail, see
Wiring Diagrams on page 16.
Note: If any of the original 10 feet supplied wire
must be replaced, use Thermostat Millivolt Wire
18 AWG Type CL2-105 C or equivalent only.
IMPORTANT: Do not hook up to standard 120
VAC household wiring.
Figure 11 - Wall Switch Installation
O
F
P
I
L
O
T
O
N
F
T
O
I
P
L
7
TPTH
TP
TH
Wall Switch
(Supplied)
Back View
To Thermopile
Route Millivolt Wires
(Supplied) Through
Electrical Conduit Bushing
ELECTRONIC MODELS
(GL36PNE/PNEP AND
VGL36PNE/PNEP)
This appliance must be properly wired to standard
120v household current through the FMI PROD-
UCTS, LLC provided wall switch before its remote
control unit can be used to activate the automatic
pilot ignition (turn replace ames ON).
WallSwitchInstallation
1. Remove the J-box cover plate from side of
appliance’s outer surround.
2. Using the 18 ga. wires coming through strain
relief grommet on side of appliance’s outer
wall to standard household 120 VAC current
through the wall switch provided, as shown in
Figure 12, page 9. For more detail, see Wiring
Diagrams, page 16.
Note: If any of the original 10 feet supplied wire
must be replaced, use 20 AWG electrical wire or
equivalent only.