FMI (V)DVF36NS Indoor Fireplace User Manual


 
www.fmiproducts.com
125078-01B 17
Check your building codes for any special
requirements for locating equipment shutoff
valve to replaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in clogged replace valves.
FIREPLACE INSTALLATION
Continued
Figure 19 - Gas Connection
Equipment Shutoff Valve
with 1/8" NPT Tap*
3" Minimum
Approved
Flexible
Gas Line
Cap Pipe Tee
Joint Nipple
Sediment Trap/
Drip Leg
Natural - From
Gas Meter (5.5"
W.C. to 10.5" W.C.
Pressure)
Propane/LP From
External Regulator
(11" W.C. to 14"
W.C. Pressure)
* The equipment shutoff valve may be sup-
plied with the appliance or you can purchase
it from your retailer.
Figure 20 - Connecting Incoming Gas Line to Flex Gas Line
Red Surface Indicates For
Propane/LP Use Only
Pilot Adjustment
Inlet Pressure Tap
Outlet Pressure Tap
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
We recommend that you install a sediment
trap/drip leg in supply line as shown in Figure
19. Locate sediment trap/drip leg where it is
within reach for cleaning. Install in piping sys-
tem between fuel supply and replace. Locate
sediment trap/drip leg where trapped matter
is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them
from going into replace gas controls. If sedi-
ment trap/drip leg is not installed or is installed
wrong, replace may not run properly.
CONNECTING FIREpLACE TO GAS
SUppLY
Installation Items Needed
5/16" hex socket wrench or nut-driver
sealant (resistant to propane/LP gas, not
provided)
1. Route exible gas line (provided by in-
staller) from equipment shutoff valve to
replace. Route exible gas supply line
through one of the access holes on side
of replace.
2. Attach exible gas line from gas supply to
control valve (see Figure 20).
3. Check all gas connections for leaks. See
Checking Gas Connections, page 18.
IN
PILOT
IN
OUT
VENT
TH
TP
TH
TP
Gas Shutoff
Valve
Flexible
Gas Line
Do NOT
Kink
1/2" NPT
Incoming
Gas Line
Note:
1) Wire connections not
shown for clarity
2) * 1/8" NPT Plugged
Tapping