FMI SVYD18NRA Stove User Manual


 
www.fmiproducts.com
113084-01L14
OPERATION
FOR YOUR SAFETY

WARNING: If you do not fol-
low these instructions exactly,
     
-

 
-

 




WHAT TO DO IF YOU SMELL GAS








 


-



 





LIGHTING
INSTRUCTIONS





1. STOP! Read the safety information
above.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch to OFF position.
  
come on automatically within
one minute when the remote
-

4. Press in and turn control knob clockwise
to the OFF position.
5. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information, page 13. If you
don’t smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
to the PILOT position.
Press in control knob for ve (5) seconds
(see step 5).
Note: You may be running this heater for
the rst time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner
(see Figure 7, page 10). If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 15.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service