INSTALLATION
Continued

Diameter Area
5" 20 sq. inches
6" 29 sq. inches
7" 39 sq. inches
8" 51 sq. inches
 Minimum Permanent

6' to 15' 39 sq. inches
15' to 30' 29 sq. inches
Damper Clamp
Damper
Clamp
Damper
Damper
 Manufactured

Figure 10 - Attaching Damper Clamp


CAUTION: Do not remove the




WARNING: You must secure

not, heater will move when you


    
   
     

-

-

  

    
    
   
    -

IMPORTANT: Make sure the heater burner
is level. If heater is not level, heater will not
work properly.
Installation Items Needed
hardware package (provided with heater)
approved flexible gas hose (provided)
(if allowed by local codes)
sealant (resistant to propane/LP gas, not
provided)
electric drill with 3/16" drill bit (metal or
masonry as applicable)
athead screwdriver
1. Apply pipe joint sealant lightly to male
threads of the tting to be threaded into
gas control. Connect approved exible gas
hose (provided for VYM models only) to
gas control tting in heater (see Figure 11).
IMPORTANT: Hold gas tting with wrench
when connecting exible gas hose.
2. Locate 2 masonry screws in hardware
package.
See chart below for minimum permanent ue
opening you must provide. Attach damper
clamp so the minimum permanent ue open-
ing will be maintained at all times.
Fitting
Flexible Gas Hose
(Provided for VYM
models only) (if
allowed by local codes)
Figure 11 - Attaching Flexible Gas Hose
to Heater