Gas Rate Summary
Burners Natural Gas LPG
Orifice size MJ/h@1 kPa Orifice size MJ/h@2.75 kPa
CG602
Auxiliary Burner (RH front) 0.85 mm 3.6 MJ/h 0.55 mm 3.9 MJ/h
Semi-Rapid Burner (LH & RH rear) 1.3 mm 8.5 MJ/h 0.8 mm 8.4 MJ/h
Wok Burner (LF front) 1.8 mm 15 MJ/h 1.05 mm 15 MJ/h
Rapid Burner (LH front) 1.55 mm 12 MJ/h 1.00 mm 13 MJ/h
CG902
Auxiliary Burner (RH front) 0.85 mm 3.7 MJ/h 0.55 mm 4.1 MJ/h
Semi-Rapid Burner (LH & RH rear) 1.3 mm 7.9 MJ/h 0.80 mm 7.9 MJ/h
Fish Burner (Centre) 1.45 mm 10 MJ/h 0.85 mm 10 MJ/h
Wok Burner (LH front) 1.8 mm 15 MJ/h 1.05 mm 15 MJ/h
GC913T
Simmer Burner (RH front) 0.85 mm 3.6 MJ/h 0.45 mm 2.7 MJ/h
Semi-Rapid Burner (LH rear) 1.22 mm 7.2 MJ/h 0.7 mm 6.2 MJ/h
Rapid Burner (LH front & RH rear) 1.45 mm 10.5 MJ/h 0.85 mm 9.3 MJ/h
Wok Burner (Centre) 1.80 mm 15.5 MJ/h 1.05 mm 14.5 MJ/h
CG913TM
Simmer Burner (RH front) 0.85 mm 3.6 MJ/h 0.45 mm 2.7 MJ/h
Semi-Rapid Burner (LH rear) 1.22 mm 7.2 MJ/h 0.7 mm 6.2 MJ/h
Rapid Burner (LH front & RH rear) 1.45 mm 10.5 MJ/h 0.85 mm 9.3 MJ/h
Wok Burner (Centre) 1.90 mm 16.3 MJ/h 1.10 mm 15.3 MJ/h
Current Information
Current Installation Instructions, Product
dimensions and specifications are available
on the Fisher & Paykel web site:
www.fisherpaykel.com