Fisher & Paykel CG602 Stove User Manual


 
4
a
e
c
d
b
f
g
Clearances
a
600 mm minimum from top of trivet to rangehood.
750 mm minimum from top of trivet to overhead exhaust fan. (Fisher & Paykel splashbacks are
750 mm high).
b
600 mm minimum from top of trivet to downward facing combustable surface. (450 mm
minimum if protected by tiles or fire resistant materials).
CG602 SERIES CG902 SERIES CG913 SERIES
c
Clearance from side edge of
product to any combustible surface
130 mm 120 mm 80 mm
d
Clearance from rear edge of
product to any combustible surface
100 mm 90 mm 90 mm
Clearance from rear edge of
product to any non-combustible
surface
10 mm 10 mm 10 mm
e
Clearance below benchtop to any
combustible surface
60 mm 60 mm 81 mm
Clearance below benchtop to
F&P DishDrawer® or F&P oven
45 mm 45 mm 81 mm
f
Ensure there is an earthed power outlet within 900 mm of the rear right-hand corner of the
product. When used with a flexible hose, the connector on the wall should be between 800
mm to 850 mm above the floor and in the region outside the width of the appliance to a
distance of 250 mm. This should be accessible with the appliance installed.
g
When protecting a wall with non-combustible material it must be at least 150 mm high.