• Unscrew the cap on the 2-way
and 3-way valve.
• After all lines are installed and
leak tested, set both the liquid
and gas line valves to fully open
position with the Allen Key for
the unit operation, as shown.
• Reinstall the cap and torque to
the specified value under Torque
Table on page 10.
Restraining the piping
• Wrap the tubing connection to
the unit with the insulation and
seal it with polyethylene tape.
You may connect an additional
drain hose. The end of the drain
outlet should keep a distance
from the ground.
Tape the connecting piping,
drain hose and wires with
polyethylene tape from bottom
upwards to the top, and secure
them to the wall.
• Fill any gap in the wall that has
been core drilled.
• Form a drip loop on the electri-
cal cable to prevent water
entering the electrical compart-
ment.