6
OPERATION
ELECTRONIC CONTROLS
Power Control
The Power Control turns the unit on and off.
Set Temperature/ Timer Display
Shows the set temperature when the unit is in operation and hours when the timer is being
set. THE TEMPERATURE DISPLAY ONLY SHOWS THE SET TEMPERATURE, NOT THE
ACTUAL ROOM TEMPERATURE.
Temperature/ Timer Hour Controls
These buttons are used to raise or lower the set temperature in increments of 1° from 66°F to
88°F. By depressing both buttons at once, the display will toggle between Celsius and
Fahrenheit. When the timer is being set, these buttons are used to change the hour setting in
increments of 1 from 00 to 24.
Mode Control
A green light will indicate which mode is currently being utilized.
Cool Mode –
The unit will circulate and cool the air.
Heat Mode (Heat Models Only) –
The unit will circulate and heat the air.
Heater Safety Feature- When heater is powered off, low fan will automatically stay on and run for 60
seconds to ensure the removal of residual heat, meanwhile, the Low Fan LED blinks until the low fan
stops.
Fan Mode –
The unit will only circulate the air.
Energy Saver Mode –
(The energy saver mode is designed to operate with Cool mode only). The fan will switch from
the set fan speed to Low whenever the compressor turns off in response to the thermostat.
When the compressor cycles back on, the unit will return to the original fan setting. Speeds
will change automatically as the temperature in the room changes.
Fan Speed Control - High, Medium, Low and Auto
The settings are adjusted with the Fan Speed Control, each time the button is depressed it
changes the setting. A green light will indicate which setting is currently being used.
When the Auto feature is selected while the air conditioner is in the Cool or Heat mode, the
fan speeds will change automatically as the temperature in the room changes. In Cool Mode
when the room reaches 7° or more above the set temperature High Fan will be used, 4° or
less above the set temperature will use Low fan. In Heat Mode when the room reaches 7° or
more below the set temperature High fan will be used, 4° or less below the set temperature
will use Low fan. At all other times the fan will use Medium fan.
Timer Control (The timer can be set to either turn the unit on or off.)
To automatically START the unit using the Timer mode:
1. Push the timer button while the power is OFF. The display will read 00. Adjust the display
to show the desired number of hours before START-UP using the Temperature/Timer
adjustment arrows.
2. The display will show the amount of time, in hours, remaining until START-UP.
3. To exit Timer mode, push the Timer button.
4. A green light next to the Timer button indicates that the timer is set.
To automatically SHUT-DOWN the unit using the Timer mode:
1. Push the timer button while the power is ON. The display will read 00. Adjust the
display to show the desired number of hours before SHUT-DOWN using the
Temperature/Timer adjustment arrows. (The display will automatically return to the set
temperature after 10 seconds.)
2. To display the amount of time left until SHUT-DOWN, push the Timer button once.
3. To exit Timer mode, push the Timer button twice.
4. A green light next to the Timer button indicates that the timer is set.
A
B
C
D
E
F
Electronic Control (Cooling Only)
Built in Three Minute Cooling Delay
Cool
High
Timer
Med
Auto
Low
Fan
Energy Save
Heat
On/Off
A
B
C
C
D
D
E
E
F
F
Temperature/Timer Display
Temperature/Timer Adjustment
Timer On/Off
Fan Speed Control
Mode Control
Power Control
A
B
Electronic Control (Heat/Cool)
Built-in three minute timing delay.
If this electronic unit will not respond to touch
pad or remote control commands, it is
necessary to unplug the unit from the electrical
outlet for five seconds and then plug the unit
back in.
Auto restart feature:
In the event of a power failure, this
feature allows the unit to resume
operation once power has been restored,
retaining the most recent settings. Upon
restoration of power, the timer mode may
need to be reset if being utilized.
CAUTION
Heat/Cool models or units with
electric heat are designed to be
used only as a supplemental heat
source.They should be used in
addition to regular heating systems
and never as the primary source of
heat.