Extech Instruments CO200 Carbon Monoxide Alarm User Manual


 
8 CO200-EU-EN v1.2 08/13
Specifications
Function Range Resolution Accuracy
CO2 0 to 9999ppm 1ppm ±(5%rdg +50ppm)
Temperature
-10 to 60°C
14 to 140°F
0.1° ±0.6°C/0.9°F
Humidity 0.1 to 99.9% 0.1%
±3%(10 to 90%)
±5%(< 10% or > 90%)
Display LCD
Sensor Type CO
2: NDIR (non-dispersive infrared) technology
Humidity: Capacitance sensor;
Temperature (air): Thermistor
Response CO
2: <2min for 90% step change
Temp: <2min for 90% step change
%RH: <10min for 90% step change
Relay 1A 30VDC/0.5A 125VAC
Operating Conditions 14 to 140°F (-10 to 60°C); < 90% RH non-condensing
Storage Conditions -4 to 140°F (-20 to 60°C); <99% RH non-condensing
Power Supply 5VDC (±10%), 500mA
Dimensions / Weight 4.6x4x4” (117x102x102mm); 7.2 oz (204g))
Maintenance
CLEANING AND STORAGE
1. The meter should be cleaned with a damp cloth and mild detergent when necessary. Do not use
solvents or abrasives.
2. Store the meter in an area with moderate temperature and humidity.