Extech Instruments CO200 Carbon Monoxide Alarm User Manual


 
4 CO200-EU-EN v1.2 08/13
3
RELAY OUTPUT
The meter is designed with a relay for connection to an external indicating or controlling device.
When CO
2 readings go over the upper limit the relay closes. The relay will open again when CO2
readings fall below the lower limit. The relay output port requires a 2.5mm STEREO phone jack
plug. The relay is: 1A 30VDC/0.5A 125VAC.
1. AC adaptor input (5VDC)
2. Alarm Relay output
3. Phone plug wiring
SETUP
(Alarm level, Temperature scale, Real Time clock)
Hold the SET button, in the normal mode, for more than 1 second to enter the setup mode.
P1.
1 CO2 ALARM: GOOD LEVEL
When entering the setup mode, P1.
0 and “CO2” are displayed on the LCD. Press the SET button
again to go into P1.
1 for setting the CO2 upper limit for the GOOD level. The current set value will
be blinking on the display.
Press the or MIN/MAX button to increase or decrease the value. Each press adjusts in 100ppm
increments. The alarm range is 0 to 700ppm.
When the value has been set, press the SET button to confirm the GOOD limit and to proceed to
P1.
2 for setting the upper NORMAL limit. Press the ESC button to exit without saving the setting.
P1.
2 CO2 ALARM: NORMAL LEVEL
P1.
2 is used for setting the CO2 upper limit for the NORMAL level. The current set value will be
blinking on the display.
Press the or MIN/MAX button to increase or decrease the value. Each press adjusts in 100ppm
increments. The alarm range is 700 to 1000ppm.
When the value has been set, press the SET button to confirm the NORMAL limit and to proceed to
P1.
3 for setting the upper POOR limit. Press the ESC button to exit without saving the setting.