Excalibur
®
P90 Zero Clearance Direct Vent Gas Fireplace
10
INSTALLATION
VENTING
INTRODUCTION
The P90 uses the "balanced fl ue" technology
Co-axial system. The inner liner vents products
of combustion to the outside while the outer liner
draws outside combustion air into the combustion
chamber thereby eliminating the need to use
heated room air for combustion and losing warm
room air up the chimney.
Note: These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be
vented directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas burning appliance.
Each direct vent gas appliance must use it's own
separate vent system. Common vent systems
are prohibited.
Side Nailing Strips
The side nailing strips come attached to the unit.
There are 2 plates, one on the top and bottom
that can be folded out as required.
Plates can be
folded out.
1) Ensure top clip screws are at top of oblong
holes before installation.
Back View of
Cover Plate
Pin Holes
Top Clip
Pins
2) Position bottom of cover plate over pins
located at the bottom of the fi rebox.
Oblong Screw
Holes
3) Bring cover plate towards the unit and hook
top clip over and behind the glass frame.
The top clip may need to be adjusted. Loosen
the 2 screws that secure the top clip to let
the cover plate settle over and behind the
glass frame. Once settled tighten screws.
TO REMOVE:
1) Remove 2 screws that secure top clip. Ensure
to hold cover plate as it will fall forward.
2) Pull out top clip that is still hooked onto
glass.
OPTIONAL COVER
PLATE TEMPLATE
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The 2 Top Standoffs must be correctly
positioned and attached to the top before unit
is slipped into position.
Top Standoff Assembly
The top standoffs are shipped in a fl at position
and must be folded into shape and attached.
1) Remove the standoffs from the fi replace
top.
2) Take each standoff and bend into the
correct shape. Bend up at the bend lines
until the screw holes in the standoff and the
pre-punched screw holes on the fi replace
top line up.
3) Attach the standoff securely to the top
with 2 screws per standoff (on opposite
corners).