Eureka HD4570 Vacuum Cleaner User Manual


 
7
Clean
Under
Use
Handle
Release
3
HOW TO USE
The upright vacuum cleaner design allows use on multiple types of
carpeting and on upholstery or bare floors with attachments. When
using the attachment tools, place the handle in the upright
position. Do not place cleaner on furniture or steps as the brush
roll may cause damage.
1. Adjust cleaner height setting knob to lowest position for maximum
cleaning. Adjust to a higher setting to make pushing easier. For
easy adjustments, tilt the cleaner back to move the knob.
2. Plug electrical cord into outlet.
3. Step on handle release. Pull handle back to a comfortable
position.
4. Push On (-) or Off (0) power switch.
Store or
Use Attachments
3
Cleaner Height Setting
WARNING: Avoid injury. Keep loose
clothing, hair, fingers, and
all other parts of body away
from any moving part (such
as the revolving brush). Turn
off the switch and unplug
the cleaner before changing
the cleaner height setting.
The front of the cleaner has an adjustment that
raises or lowers the cleaner base to match the type
of carpet. With the cleaner cord unplugged, set the
adjustment to lowest setting for maximum cleaning.
If the cleaner is difficult to push, move adjustment
to next highest setting until cleaner is comfortable
to push. The brush roll must reach the carpet for
effective cleaning.
Make each adjustment with cleaner switch off
and cord disconnected from outlet. For ease
in moving the adjustment knob, place handle in
operating position and tilt cleaner back to remove
weight from front wheels.
3
Handle
Release
ON/OFF
THERMAL CUT OFF
This cleaner has a special thermostat that protects the cleaner
in case of motor overheating. If the cleaner suddenly turns off,
follow this procedure:
1. Push power switch off.
2. Unplug cleaner.
3. Check for source of overheating problem (i.e. full bag, clogged
hose or clogged filter).
4. If a full bag, clogged hose or clogged filter is found, replace the
bag, unclog the hose or replace the filters.
5. Wait at least 30 minutes before attempting to reuse the cleaner.
6. After 30 minute cool down period, plug the cleaner in and push
the power switch on. The cleaner should turn on.
7. If the cleaner still does not operate, take it to any Eureka Authorized
Service Center for repair.
4
LOW HIGH
1
2