11
How To Replace Bags–Style AA
NOTE: Turn off the switch and unplug the electrical cord before changing dust bag. Never operate the vacuum
cleaner without the dust bag or the filter.
To Remove Bag:
Front
Cover
A
A. Remove front cover by pulling out on the front
cover latch and lifting the front cover upward
and out.
B. Remove left side of bag collar from bag collar
retainer. Grasp bag collar; pull down slightly
and out to remove bag.
To Replace New Bag:
C. Fold sides on new paper bag below bag
collar.
D. Align bag collar hole and notch with hose
tube.
E. Place rear of bag collar on ledges. Push
back and rotate upward until firmly in
place. Make sure collar snaps into position
and hose tube is securely inserted into bag
collar hole.
F. Tuck bag into bottom and along sides.
G. Align front cover tabs and close cover.
Make sure paper bag is not caught under
the front cover.
D
E
C
Bag
Side
E
We recommend using only Genuine Eureka
Standard AA Bags, part number 58236.
B
Bag
Collar
Front Cover
Latch
F