Eureka 4480 Vacuum Cleaner User Manual


 
Cleaner Height Setting
WARNING: Avoid injury. Keep loose clothing,
hair, fingers, and all other parts of
body away from any moving part
(such as the revolving brush). Turn
off the switch and unplug the
cleaner before changing the cleaner
height setting.
The front of the cleaner has an adjustment that raises
or lowers the cleaner base to match the type of
carpet. With the cleaner cord unplugged, set the
adjustment to lowest setting for maximum cleaning.
If the cleaner is difficult to push, move adjustment to
next highest setting until cleaner is comfortable to
push. The brush roll must reach the carpet for
effective cleaning.
NOTE: For ease in moving the adjustment knob,
place handle in operating position and
tilt cleaner back to remove weight from
front wheels.
NOTE: When handle is in upright position, brush
roll is lifted off carpet. This is normal.
Height adjustment will not change brush
roll level until the cleaner’s handle is
moved into the operating position.
Clean
Under
Use
Handle
Release
3
7
HOW TO USE
The upright vacuum cleaner design allows use on multiple types of
carpeting and on upholstery or bare floors with attachments. When
using the attachment tools, place the handle in the upright
position. Do not place cleaner on furniture or steps as the brush
roll may cause damage.
1. Adjust cleaner height setting knob to lowest position for maximum
cleaning. Adjust to a higher setting to make pushing easier. For
easy adjustments, tilt the cleaner back to move the knob.
2. Plug electrical cord into outlet.
3. Step on handle release. Pull handle back to a comfortable position.
4. Push On/Off power switch.
Store or
Use Attachments
LOW HIGH
Handle
Release
ON/OFF
THERMAL CUT OFF
This cleaner has a special thermostat that protects the cleaner
in case of motor overheating. If the cleaner suddenly turns off,
follow this procedure:
1. Push on/off pedal once.
2. Unplug cleaner.
3. Check for source of overheating problem (i.e. full cyclonic
cassette, clogged hose or clogged filter).
4. If a full cyclonic cassette, clogged hose or clogged filter is found,
empty the cyclonic cassette, unclog the hose or replace the filters.
5. Wait at least 30 minutes before attempting to reuse the cleaner.
6. After 30 minute cool down period, plug the cleaner in and push
the switch pedal. The cleaner should turn on.
7. If the cleaner still does not operate, take it to any Eureka
Authorized Service Center for repair.
4