Installation
DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:
1. Check clearances to combustibles (see INSTALLATION - CLEARANCES TO COMBUSTIBLES
- FREESTANDING, INSTALLATION - ALCOVE CLEARANCES - FREESTANDING, and INSTALLATION
- CLEARANCES TO COMBUSTIBLES - FIREPLACE INSERT.
2. Do not obtain combustion air from an attic, garage or any unventilated
space. Combustion air may be obtained from a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or connect
it to an existing masonry or metal chimney (must be lined if the chimney
is over 6” (15 cm) diameter, or over 28 inches² (180 cm²) cross sectional
area). An interior vent can be used with approved pipe passing through the
ceiling and roof.
5. Locate the stove in a large and open room that is centrally located in the
house. This will optimize heat circulation.
6. The power cord is 8 feet (2.43 m) long and may require a grounded extension
cord to reach the nearest electrical outlet.
REMOVING PELLET STOVE FROM PALLET:
To remove your new stove from its pallet, remove the two (2) screws securing the bottom to the pallet.
Freestanding: One screw can be easily seen from behind but to access the second screw the ashpan must
be removed.
Fireplace Insert: There is one screw on either side of the bottom.
Figure 6: Removing Freestanding Stove From the Pallet. Figure 7: Removing Insert Stove From the Pallet.