Enviro EG-40 Indoor Fireplace User Manual


 
8. ROUTINE MAINTENANCE
Periodically check to ensure that the "B-Vent" venting
system is clear and that a negative draft is present when
the unit is operating.
Periodically check the pilot and burner flames
CLEANING OF GLASS
Do not clean glass when hot
It will be necessary to clean the ceramic glass
periodically. During a cold start up condensation will
sometimes form on the glass, this is a normal condition
with all gas fireplaces and stoves. However, sometimes
this condensation can allow dust and lint to cling to the
glass surface. Also, sometimes the initial paint curing of
the appliance can leave behind a slight film on the glass.
This is a temporary problem. It is therefore
recommended that the glass be cleaned initially after
about the first two weeks of use.
After that, depending upon the amount of use, cleaning
should be required no more than two or three times per
season.
To clean the door, use a mild glass cleaner and a soft
cloth. Abrasive cleaners will damage the glass surface.
OPENING THE GLASS DOOR
Turn unit off and wait until the appliance has cooled
down.
1. Open the right hand hinged side flap that will expose
a door fastener. Using a 1/2" wrench, loosen off the
fastener.
2. Due to the shape of the bay window door. You must
also open the left-hand side flap before attempting to
open the Bay window door.
3. Ensure the door is properly fastened after cleaning
before attempting to re-light the appliance.
4. Remove all fingerprints from all gold before lighting
this appliance.
TO REPLACE DOOR AND GLASS
ASSEMBLY
The glass in this appliance is an integral part of the door
assembly. If the glass is damaged or broken a
replacement door assembly including glass must be
fitted.
open door fully
Lift door vertically so that the hinge pins lift out of
hinge receivers.
Return assembly to dealer.
Your ENVIROGAS Dealer must replace door and glass
assembly as a complete unit. No substitute materials are
allowed
.
FOR CLEANING THE INSIDE OF THE
FIREBOX
Remove the log set carefully from the firebox. Gently
remove the embers and place on a piece of paper towel.
Until ready to replace.
Vacuum the firebox thoroughly. Carefully clean off any
dust on the logs and remove any lint from the main
burner and pilot burner.
After carefully replacing the logs and embers in their
correct positions, and the door has been resealed, re-
light the pilot, following the instructions on the attached
label.
CLEARANCES MUST BE SUFFICIENT TO ALLOW
ACCESS FOR MAINTENANCE AND SERVICE
LUBRICATING THE BLOWERS
EVERY 6 MONTHS
1. Turn the unit off and remove the log set.
2. Remove the burner tray assembly by removing the
screw on either side of the tray, between the front and
rear burners. Lift tray out.
3. Remove the 8 screws that hold the blower mounting
plate to the back firewall.
4. Carefully pull the blower assembly into the firebox,
exposing the blower lubricating holes (located on the top
of the motor housing on either side of the label). Add 2
drops of SAE 20 oil.
If removal of the blower is necessary, disconnect the 2
black blower leads from the terminal block, located on
the floor of the fan compartment. Remove the blower.
5. To re-install, check gasket and reverse steps 1
through 4.
10