Enviro EF THERMO 28 Stove User Manual


 
Floor Protection
C
B
A
Maintain these clearances to combustibles.
A) Side wall to unit 6 inches (153 mm)
B) Back wall to unit 1 inch ( 25 mm)
C) Adjacent wall to corner of unit 1 inch ( 25 mm)
- Mantle (Hearth Mount) 8 inches (203 mm)
Installation
CLEARANCES TO COMBUSTIBLES:
ALCOVE CLEARANCES:
This unit may be installed in an alcove. Maintain
clearances to combustibles.
Minimum Alcove width 36 inches ( 914 mm)
Minimum alcove height 48 inches (1220 mm)
Maximum alcove depth 30 inches ( 762 mm)
Install vent at clearances specified by
the vent manufacturer.
3
0
"
(
75
c
m
)
48"
(120cm)
36" (90cm)
Figure 15
Figure 14
12
This unit can be installed on a combustible floor
due to the built in pedestal hearth pad (for example
linoleum, hardwood flooring). If combustible
flooring is underneath the unit 6 inches (153 mm)
on either side and to the front must be protected
by non-combustible material. If this unit is to be
installed onto a carpeted surface, a hearth pad
must be used for stability.
NOTE: These dimensions are minimum clearances
but it is recommended that you ensure sufficient
room (20” [508 mm]) on either side) for servicing,
routine cleaning and maintenance.
Do not block any of the air intake grills.