Enviro C-10608 Stove User Manual


 
19
 
 
 
 
 
 
 
Installation
THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION- RECOMMENDED:
Figure 15: Venting horizontally with rise.
A 45° elbow with a rodent screen may
be used in place of the termination
cap (or stainless steel termination
hood).
THROUGH CONCRETE WALL WITH VERTICAL RISE INSTALLATIONS:
Wall framing
Wall thimble
Termination cap
Vertical section
of vent pipe
Horizontal frame
for thimble
Clean out tee
90
o
elbow
EF 5
Concrete Wall
A 45° elbow with a rodent screen may
be used in place of the termination
cap (or stainless steel termination
hood).
Installation to use if there is a concrete
or retaining wall in line with exhaust
vent on pellet stove.
The termination must be 12 inches
(30 cm) from the outside wall and 12
inches (30 cm) above the ground.
Figure 16: Venting with concrete wall behind unit .