29
Installation
The ue collar is removable for installations
into replaces with low openings.
a) Remove the rst two (2) front secondary
air tube and ceramic bafes, if installed
(see CERAMIC BAFFLE INSTALLATION).
b) Unscrew the nut on top of the inside
of the rebox, using a
9
/16” wrench or
socket (see Figure 31). The ue plate
clamp will slide off the hook/clamp.
c) Pull the hook/bolt and the removable
ue collar off the top of the unit.
Figure 32: Attaching removable ue.
Figure 33: Leveling leg.
Nut
Hook/bolt
Flue plate clamp
d) Attach the ue collar to the venting pipe using
sheet metal screws.
e) Push the unit into place while trying to keep the
collar attached to venting close to the opening
on the top of the unit.
f) Using the hook/bolt, grab the ue collar by the
rod through the center and pull it into place (see
Figure 32).
g) Slide the ue plate clamp over the end of the
hook/bolt and screw the nut back on to the
hook/bolt.
h) Re-install ceramic bafes and the rst two (2)
front secondary air tube (see CERAMIC BAFFLE
INSTALLATION).
3. There are two (2) leveling legs (shown in Figure 33),
one on each side, at the back of the unit. Adjust the
legs using a
9
/16” wrench to ensure the unit is stable.
Figure 31: Attaching removable ue.
4. Screw or nail the metal plate provided by the manufacturer to the
inside of the replace.
METAL TAG: “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE
A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED
PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.”