Specifications
CLEARANCES TO COMBUSTIBLES - 1200 INSERT:
A Minimum clearance to an unshielded side wall
10” (254 mm)
B Minimum clearance to an unshielded 8” (203 mm) mantle
21” (533 mm)
C Minimum top facing (protruding ” [19 mm]) clearance
17” (445 mm)
D Minimum side facing (protruding ” [19 mm]) clearance
1” (25 mm)
E † From front of unit to edge of oor protection
USA 16” (406 mm)
CND 18” (450 mm)
F † From side/back of unit to edge of oor protection
USA 6” (152 mm)
CND 8” (200 mm)
† FLOOR PROTECTION:
If unit is raised 0” - 2” (0mm-51mm); 1” (25mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised 2” - 8” (51mm-203mm); ” (13mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised greater than 8” (203 mm) or more; any non-combustible material can be used.
Masonry Zero Clearance
Minimum Depth 13” (343mm) 14” (279mm)
Minimum Width at back of replace 22” (568mm) 23” (584mm)
Minimum Width at front of replace 27” (686mm) 27” (692mm)
Minimum Width at front of replace to include shroud 33” (857mm) 34” (864mm)
Minimum Height 19” (489mm) 20” (508mm)
CLEARANCES TO COMBUSTIBLES - 1700 INSERT:
A Minimum clearance to an unshielded side wall
10” (254 mm)
B Minimum clearance to an unshielded 8” (203 mm) mantle
24” (610 mm)
C Minimum top facing (protruding ” [19 mm]) clearance
19” (495 mm)
D Minimum side facing (protruding ” [19 mm]) clearance
1” (25 mm)
E † From front of unit to edge of oor protection
USA 16” (406 mm)
CND 18” (450 mm)
F † From side of unit to edge of oor protection
USA 6” (152 mm)
CND 8” (200 mm)
† FLOOR PROTECTION:
If unit is raised 0” - 2” (0mm-51mm); 1” (25mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised 2” - 8” (51mm-203mm); ” (13mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised greater than 8” (203 mm) or more; any non-combustible material can be used.
Masonry Zero Clearance
Minimum Depth 18” (457mm) 18” (470mm)
Minimum Width at back of replace 22” (568mm) 23” (584mm)
Minimum Width at front of replace 27” (686mm) 27” (692mm)
Minimum Width at front of replace to include shroud 33” (857mm) 34” (864mm)
Minimum Height 19” (489mm) 20” (508mm)
Table 3: 1200 Insert Clearance to Combustibles.
Table 5: 1700 Insert Clearance to Combustibles.
Table 4: 1200 Insert Minimum Fireplace Size.
Table 6: 1700 Insert Minimum Fireplace Size.