Enviro 50-1573 Stove User Manual


 
OPERATING YOUR PELLET STOVE:
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. Keep hopper lid closed
except during re-fuelling.
CAUTION: When operating during adverse weather, such as high winds or freezing rain, if the unit
exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust
outlet.
PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the
ignitor tube. Check the hopper for enough pellets to start the unit.
Figure 3: Thermostat Switch in
MANUAL position.
Figure 4: Thermostat Switch in
HIGH/LOW position.
 



 

 
1
2
3
4
5
6
7
8
9
 



 

 
 



 

 
1
2
3
4
5
6
7
8
9
 



 

 
Figure 5: Thermostat Switch in
AUTO/OFF position.
 



 

 
1
2
3
4
5
6
7
8
9
 



 

 
Note: The thermostat mode can be changed during normal
operation.
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
To START: Press the ON / OFF button. The stove will turn on. The
system light will flash. The Auger Light will flash with each pulse of the
auger (the Auger Feed Rate is pre-programmed during start-up). The
Heat Level Indicator will show the Heat Level that the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to
be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see
OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).
When a fire has been established, the System Light will turn solid and the convection blower will turn on
(after approximately 10 - 15 minutes), and the Auger Light will continue to flash to the corresponding
Heat Level setting.
To OPERATE: Press the Heat Level button to change the desired Heat Level Output setting.
The speed of the convection blower is controlled by the setting of the heat level. This blower can be
turned OFF by depressing the convection blower control button. For the best efficiency, the convection
blower should be left on at all times.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different
quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the
low setting is too hot for the room (see “OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).
HIGH/LOW MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat calls for heat (contacts are
closed) the stove settings are adjustable as per Manual Mode. When
the thermostat contacts open, the HEAT LEVEL and Fans will drop
down to the LOW setting until the thermostat contacts close again.
*The LOW heat setting can be adjusted for different fuel qualities
(see “OPERATING INSTRUCTIONS - CONTROL BOARD FUNCTIONS”). The stove will
come back to the previous HEAT LEVEL setting when the thermostat
contacts close again.
AUTO/OFF MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat contacts close, the unit will light
automatically. Once up to temperature, the stove operates the same as
Operating Instructions
8