Enviro 50-1531 Stove User Manual


 
Operating Instructions
OPERATING YOUR PELLET STOVE:
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. Keep hopper lid closed
except during re-fuelling.
CAUTION: When operating during adverse weather, such as high winds or freezing rain, if the unit
exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust
outlet.
PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the
ignitor tube. Check the hopper for enough pellets to start the unit.
Note: The thermostat mode can be changed during normal operation.
Figure 3: Thermostat Switch in
MANUAL position.
Figure 4: Thermostat Switch in
HIGH/LOW position.
Figure 5: Thermostat Switch in
AUTO/OFF position.
6
7
8
1
2
3
4
5
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
To START: Press the ON / OFF button. The stove will turn on.
The system light will flash. The Auger Light will flash with each pulse
of the auger (the Auger Feed Rate is pre-programmed during start-
up). The Heat Level Indicator will show the Heat Level that the stove
will run at after start-up.
If this is the first time the unit has been started or the unit has run
out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop
into the Burn Pot Liner (see “OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).
When a fire has been established, the System Light will turn solid and the convection blower will turn on
(after approximately 10 - 15 minutes), and the Auger Light will continue to flash to the corresponding
Heat Level setting.
To OPERATE: Press the Heat Level button to change the desired Heat Level Output setting.
The speed of the convection blower is controlled by the setting of the heat level. The Convection Blower
does not operate when on Heat Output is on LOW, this is to prevent over cooling of the unit.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different
quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel) or if the low
setting is too hot for the room (see “OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).
HIGH/LOW MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat calls for heat (contacts are
closed) the stove settings are adjustable as per Manual Mode. When
the thermostat contacts open, the HEAT LEVEL and Fans will drop
down to the LOW setting until the thermostat contacts close again.
*The LOW heat setting can be adjusted for different fuel qualities
(see “OPERATING INSTRUCTIONS - CONTROL BOARD FUNCTIONS”). The stove will
come back to the previous HEAT LEVEL setting when the thermostat
contacts close again.
AUTO/OFF MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat contacts close, the unit will
light automatically. Once up to temperature, the stove operates the
same as in MANUAL. When the thermostat contacts open, the stove’s