Enviro 1700-V Insert Stove User Manual


 
Installation
Leveling Legs
Figure 14: Removable ue collar in place.
Figure 15: Leveling legs.
SURROUND PANEL SEALED INSTALLATION FOR USA ONLY:
Note: Though this is an allowable installation, we do not recommend it because of the possibility of poor
draft, and therefore poor stove performance.
Before starting this type of installation refer
to INSTALLATION - MASONRY FIREPLACE INSTALLATION
- INSERT for additional information. For
clearances refer to SPECIFICATIONS - CLEARANCES
TO COMBUSTIBLES - 1200-V INSERT and
SPECIFICATIONS - CLEARANCES TO COMBUSTIBLES -
1700-V INSERT.
1. Before the face plate is installed onto
the unit, glue a 6” (150mm) wide R20
berglass insulation strip around the
perimeter of the back of the panels using
RTV silicon or stove gasket cement.
When the face plate is installed onto
the unit the insulation must overlaps the
replace opening to form a seal between
the masonry replace and the unit’s face
plate. Let the silicon or cement dry.
2. To make the installation of the surround
panel onto the unit easy have the unit 6”
(150mm) out from the replace,
3. Push the insert into the replace, allowing
the insulation to form a seal between
the panels and the replace. Tuck any
exposed insulation behind the face plate.
Figure 16: Installation with Surround Sealed.
Masonry Fireplace
Mantel
Damper Removed
or Fastened Open
Surround Panel
USA 16” (406 mm)
CND 18” (450 mm)
Insulation Around the
Back of the Face Plate
       
     
       
        
      
     
    
        
 
4. Screw or nail the provided metal plate with the
wording “THIS FIREPLACE HAS BEEN ALTERED
TO ACCOMMODATE A FIREPLACE INSERT AND
SHOULD BE INSPECTED BY A QUALIFIED PERSON
PRIOR TO THE RE-USE AS A CONVENTIONAL
FIREPLACE.” to the inside of the replace.
18