Page | 21
THERMOSTAT OPERATION
Thermostat Installation
1. Unplug the unit and remove the back panel of the stove.
2. Locate the thermostat connect block, labeled J18, on the rear of the control
board, near the bottom (See image below and pg. 43 of this manual for a
control board diagram). It will have a small wire “jumper” installed in it
from the factory. This jumper bypasses the thermostat and should be saved.
3. Loosen the two screws using a small slotted “jewelers” screwdriver and
remove the “jumper.”
4. Insert the two thermostat wires in place of the “jumper” and retighten the
screws.
5. Reinstall the back panel and mount the thermostat; the control board
automatically reads the thermostat and your stove is now ready for
thermostat operation.
Connect
thermostat
wires here
(J18)