INSTALLATION
Mobile Home Installation
• As with all installations involving this unit, the use of outside combustion air is
mandatory and MUST be used. Please see the “Outside Air” section on page
14 for more information regarding outside air connections.
• The pellet stove MUST be secured to the floor of the mobile home using lag
bolts and the holes provided in the bottom of the pedestal for this purpose.
• The pellet stove MUST be grounded with #8 solid copper grounding wire (or
equivalent), terminated at each end with an NEC approved grounded device.
• Carefully follow all clearances listed in the appropriate section of this manual
AND follow the venting manufacturer’s minimum clearance requirements.
Similarly, be certain the venting system used is approved for mobile home use.
• Installation must be accordance with Manufacturers Home & Safety Standard
(HUD) CFR 3280, Part 24 as well as any applicable local codes.
WARNING
DO NOT INSTALL IN A SLEEPING ROOM.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME
FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
Caution
NEVER draw outside combustion air from:
• Wall, floor or ceiling cavity.
• Enclosed space such as an attic, garage or crawl space.