INSTALLATION
ApprovedVentingMethod1
:ThroughtheWall
Generallythesimplestinstallationmethod,
ventingthroughthewallusingourAC3000
kit(orsimilarventingsystem)isalsothe
preferredventingmethod.Itminimizes
horizontalpipe,allowsthestovetobe
installedclosetothewallandkeepsthe
cleanoutteeontheoutsideofthe
house,
foreaseofcleaning.
Wheninstallinganyventingsystem,TypeL
orTypePLpipemustbeusedandall
clearancestocombustibles(listedbythe
pipemanufacturer)mustbestrictly
adheredto.
Usethepipemanufacturer’sapproved
thimbleforpassingthroughacombustible
wall,andmaintainatleasttheminimumclearancestocombustibles.
Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepellet
stoveandattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
Securethepelletventtotheoutsideofthehouseusingawallstrapjustbelowthe90
degreeelbow.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoing
so).
Ifthepelletventpipebeingusedisnota“Twist
Lock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveor
usinganalternativemethod,asdescribedinthe“OutsideAir”section,onpage14.
Thisinstallationtypecanbe
modifiedforbasement(Basementinstallationsshouldalways
beperformedbyaprofessionalinstaller)orotherinstallationswhereintheteeandvertical
sectionofthepipewouldbeinsidethehomeandtheventingsystemwouldsimplypass
horizontallythroughthethimbleandthenterminate.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(