B. Gaskets
This unit comes with a gasket around the door, which should be replaced every two
years. To replace the door gasket (Part #AC-DGKC) the old gasket must first be
completely removed. This may require you to scrape the channel free of old gasket and
adhesive prior to adding the cement and new five-eighth inch (5/8”) rope gasket. After
attaching the new gasket the door should be closed and latched for twenty-four (24)
hours to allow the cement to harden.
If you are replacing the window gasket (Part #AC-GGK), the gasket already has
adhesive on one side. Remove the paper on the adhesive side and place it around the
outside edge of the glass --forming a “U” with your fingers and running it around the
outer perimeter does this. The door and glass gasket can be ordered from your dealer or
directly from the factory (PARTS ORDERS ONLY dial 800-516-3636).
C. Firebrick (Part #AC-SB & AC-LB)
This stove is equipped with high density, high temperature firebrick. If the brick
becomes chipped or cracked, especially on the sides of the firebox, it should be
replaced. This stove requires fifteen large brick and ten small brick. These items can be
ordered from your dealer or from the factory.
D. Finish (Part #AC-MCSP)
Your stove has been painted with 1200 degree Metallic Charcoal paint that will retain
its original appearance for years. If your stove should get wet, some rust spots may
appear -- these can be removed with plain steel wool and touched up with new paint. We
recommend using our paint as others may not be able to withstand the high surface
temperatures. This item can be ordered from your dealer or from the factory.
E. Blower System
This unit has a four-tube blower system, which consists of a manifold welded into the
top of the unit. At the rear of the stove is a blower duct where the room air blower
(Part #AC-16) attaches. This blower is a squirrel cage type motor with bearings that will
require some lubrication; prior to each season it is a good idea to oil the bearings
through the openings on each end of the motor housing. Any lightweight type household
oil can be used for this procedure.
F. Glass Cleaning
Depending on the type wood and the mode in which you are operating the unit it may
be necessary to clean the glass several times per week. Let the stove cool down, then
clean the glass with a stove glass cleaner or a solution of ammonia mixed with water.
You may order parts and options on our web site: www.englandsstoveworks.com ,
or by calling (800) 516-3636