14
Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters OperatingInstructionsandOwner’sManual
FIGURE 6
LOW PRESSURE, MAIN GAS LINE
SEE FIGURE 2 FOR PROPER INLET PRESSURES
FOR HIGHER PRESSURES THAN SHOWN ABOVE
CONTACT FACTORY FOR PROPER REGULATOR
ON THREADED PIPES USE A PIPE COMPOUND WHICH
IS RESISTANT TO THE ACTION OF ALL GASES
MUST BE RESISTANT TO PROPANE
TYPICAL LOW PRESSURE
STANDARD INSTALLATION
HEATER
MOUNTING HOLES-4 REQ’D
SIDE VIEW
½ PSI MAX.
SHUT-OFF VALVE
TEE
DRIP LEG
CAP
HIGH ALTITUDE OPERATION
Please contact the factory for a detailed High Altitude 1.
ConversionKittosuityourspecicneed.
1.1 Be prepared to answer factory questions regard-
ing: Type of fuel for the proposed appliance con-
version,gaspressureavailableatsite,andspecic
altitude at site.
“The conversion shall be carried out by a manufac-2.
turer’sauthorizedrepresentative,inaccordancewith
the requirements of the manufacturer, provincial or
territorial authorities having jurisdiction and in accor-
dance with their requirements.”
High Altitude Conversion Kits will include high 3.
altitude rating plate with stamped data, necessary
oricesorburnerasrequiredforspecicneedand
additional installation instructions.
In Canada, Heater installations at High Altitudes shall 4.
comply with the applicable construction provisions of
thecurrentstandardCAN1-2.17,gasredappliances
for use at high altitudes.
RIGID OR FLEXIBLE GAS
LINE TO HEATER
PIPE NIPPLE