FIGURE 6
LOW PRESSURE, MAIN GAS LINE
SEE FIGURE 2 FOR PROPER INLET PRESSURES
FOR HIGHER PRESSURES THAN SHOWN ABOVE
CONTACT FACTORY FOR PROPER REGULATOR
ON THREADED PIPES USE A PIPE COMPOUND WHICH
IS RESISTANT TO THE ACTION OF ALL GASES
MUST BE RESISTANT TO PROPANE
TYPICAL LOW PRESSURE
STANDARD INSTALLATION
HEATER
MOUNTING HOLES-4 REQ’D
SIDE VIEW
½ PSI MAX.
SHUT-OFF VALVE
TEE
DRIP LEG
CAP
HIGH ALTITUDE OPERATION
Please contact the factory for a detailed High Altitude 1.
ConversionKittosuityourspecicneed.
1.1 Be prepared to answer factory questions regard-
ing: Type of fuel for the proposed appliance con-
version,gaspressureavailableatsite,andspecic
altitude at site.
“The conversion shall be carried out by a manufac-2.
turer’sauthorizedrepresentative,inaccordancewith
the requirements of the manufacturer, provincial or
territorial authorities having jurisdiction and in accor-
dance with their requirements.”
High Altitude Conversion Kits will include high 3.
altitude rating plate with stamped data, necessary
oricesorburnerasrequiredforspecicneedand
additional installation instructions.
In Canada, Heater installations at High Altitudes shall 4.
comply with the applicable construction provisions of
thecurrentstandardCAN1-2.17,gasredappliances
for use at high altitudes.
RIGID OR FLEXIBLE GAS
LINE TO HEATER
PIPE NIPPLE