The replace is designed to accept a gas line for connection to the
gas valve. Have the line installed by a qualied service person in
accordance with all building codes. Consult local building codes
to properly size the gas supply line leading to the connection of the
valve. The state of Massachusetts requires that a exible appliance
connector cannot exceed three feet in length.
Gas access holes are provided through the side panel(s) of the
replace. .
Check gas type. Use only the gas type indicated on the rating plate.
If the gas listed on the plate is not your type of gas supply, DO NOT
INSTALL. Contact your dealer for proper model.
Always use an external regulator to reduce the supply tank pressure
to a maximum of 10.5" w.c. (NAT), or 13" w.c. (LP) See page
10.
WA RN IN G: CO NN EC TI ON D IR EC TLY T O A N
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.

GAS LINE CONNECTION
GAS LINE
ACCESS
HOLES