CLEARANCES
Figure 4a - See Through Fireplace Clearances
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFHOOD)
1 3/4”MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFHOOD)
1 3/4”MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
Figure 4b - Peninsula Fireplace Clearances
Sidewall Clearances: The clearance from the inside of the replace
to perpendicular combustible side wall should not be less than
1 3/4". See Figures 4a and 4b.
       
minimum
Fireplace Side and Back Clearances: The replace outer casing
side(s) require a minimum 1/2" clearance to combustibles.
Top Framing and Finishing: Combustible framing may rest on
top of standoffs. Combustible nishing materials may extend to
the top standoff screws on the front edge of the top outer wrap.

FIREBOX
STAND OFF
COMBUSTIBLE
FINISHED WALL
OR MANTEL
2X4
HEADER
TOP OUTER
WRAP
FINISH WITH TRIM KIT
OR NON-COMBUSTIBLE
MATERIAL AS DESIRED.
