WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
3. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
TO TURN OFF GAS TO APPLIANCE
1. Set thermostat (gas control knob) to lowest setting.
2. Turn off all electric power to appliance if service is to be
performed (if applicable).
LIGHTING INSTRUCTIONS
in for about one (1) minute after the pilot is lit. Release
knob and it will pop back up. Pilot should remain lit. If
it goes out, repeat steps 4 through 8.
If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
9. Attention! Gas control has an INTERLOCK latching
device. When the pilot is initially lit and the safety magnet
is energized (pilot stays "ON") the INTERLOCK latching
device becomes operative. If the gas control is turned to
the "OFF" position or gas flow to the appliance is shut
off, the pilot cannot be relighted until the safety magnet
is de-energized (approximately 60 seconds). There will
be an audible "click" when the safety magnet in the gas
control is de-energized. Pilot can now be relighted. Repeat
steps 4 through 8.
10. Turn gas control knob counterclockwise to
"5".
11. Turn on all electric power to appliance (if applicable).
12. Set thermostat (gas control knob) to desired setting from
"5" to "1 ".
1. STOP! Read the safety information above.
2. Set thermostat (gas control knob) to lowest setting.
3. Turn off all electric power to the appliance (if appli
-
cable).
4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5. Wait ten (10) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety information above. If you don't
smell gas, go to the next step.
6. Find pilot - the pilot is
in front of the rear log
7. Turn gas control knob
counterclockwise
to
"PILOT."
8. Push in gas control knob all the way and hold in. Repeat
-
edly push the piezo ignitor button until pilot is lit (or use
a match to light pilot). Continue to hold the control knob
VFP(32,36)FP(20,21) LIGHTING INSTRUCTIONS