Empire Comfort Systems VFD36FB0L-1 Indoor Fireplace User Manual


 
23200-0-1206Page 8
The firebox is designed to accept a 3/8-inch gas line for an approved
vent-free gas logset. Have the line installed by a qualified service
person in accordance with all building codes. Consult local building
codes to properly size the gas supply line leading to the 3/8-inch
hook-up at the unit. The state of Massachusetts requires that a
flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox.
See
Figure 11. On models with ceramic brick panels installed, carefully
remove the indented knockout in the ceramic brick panel using a
drill or utility knife. See Figure 12.
When installing optional ceramic fiber side panels into firebox,
lay panel on a flat surface. Remove the gas line knockout (round
depression) in the appropriate side panel using a drill or utility
knife.
After the brick panel knockout is removed, the firebox wrap may
have a round metal knockout that must be removed also. Use a
screwdriver to punch out the metal knockout.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of
gas supply, DO NOT INSTALL. Contact your dealer for proper
model.
Always use an external regulator for all LP fireboxes to reduce the
supply tank pressure to a maximum of 14" w.c. This is in addition
to the regulator fitted to the log set.
WAR NIN G: CONN ECT ION DIR ECT LY TO A N
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.
Install only a ANSI Z21.11.2 vent-free log set into this firebox.
Figure 11
Extended Hoods
If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that
will extend out 2" farther out into the room. Contact your local dealer for details.
Finishing
All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-
combustible material.
Hearth extensions are recommended, but not required for these fireboxes.
VB4H32BL Standard Black VB4H36BL Standard Black VB4H42BL Standard Black
VB4H32BR Polished Brass VB4H36BR Polished Brass VB4H42BR Polished Brass
VB4H32SS Stainless Steel VB4H36SS Stainless Steel VB4H42SS Stainless Steel
VB4H32HP Hammered Pewter VB4H36HP Hammered Pewter VB4H42HP Hammered Pewter
GAS ACCESS HOLES
Figure 12
INSTALLING HOOD (continued)
GAS LINE CONNECTION