Installing Vent Components (Figure 36)
Begin the vent system installation by installing the first Simpson
Duravent component, 90° elbow to the starting collars or straight
pipe on the top of the appliance, then the straight pipe length and
then horizontal or vertical termination kit.
NOTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The
inner flue joints do not require any sealant.
Simpson Duravent vent system components lock into place by
sliding the concentric pipe section with four (4) equally spaced
interior beads onto the appliance collar or previously installed
component end with four (4) equally spaced indented sections.
When the internal beads of each starting outer pipe line up, rotate
pipe section clockwise 90° (approximately 3 inches). The vent pipe
is now locked together.
Continue adding components per the pre-planned vent system
configuration. Be certain that each succeeding vent component
is securely fitted and locked into the preceding component in the
vent system.
Figure 36
WALL THIMBLE
(MAXIMUM
OF
THREE 90 ELBOWS)
(MAXIMUM
OF
TWO 90 ELBOWS)
Special Venting Components
Simpson Dura-Vent
Can be purchased from Simpson Duravent or from
Empire Comfort Systems, Inc.
Part Number Description
SD-1208 6" Pipe Length
SD-1207 9" Pipe Length
SD-1206 12" Pipe Length
SD-1204 24" Pipe Length
SD-1203 36" Pipe Length
SD-1202 48" Pipe Length
SD-1211 Adjustable Pipe Length 11 - 14 5/8"
SD-1284 Horizontal Square Termination Cap
SD-1250 Vinyl Siding Standoff
SD-1245 45° Elbow
SD-1290 90° Elbow
SD-1249 Wall Firestop
SD-1263 Ceiling Firestop
SD-1243 Roof Flashing - 0/12 to 6/12 Roof Pitch
SD-1253 Storm Collar
SD-91291 High Wind Vertical Top
SD-1281 36" Snorkel
SD-1282 14" Firestop Snorkel
SD-1247 Wall Thimble Firestop
Special DV Vent Kits - Simpson Duravent and Empire Comfort Systems, Inc.
Can be purchased from Empire Comfort Systems, Inc.
DVVK-5R
Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to 12 inch wall
thickness, Includes SD-1208, SD-1247, and SD-2184
DVVK-5T
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 4
to 6 inch wall thickness, Includes SD-1290, SD-1284, SD-1208
and SD-1247
DVVK-5V
Direct Vent Fireplace Vent Kit - Vertical, Includes SD-1291,
SD-1253, and SD-1243
VENT SYSTEM IDENTIFICATION