EMI UNH-T2H-T3H-T4H Heat Pump User Manual


 
http://www.enviromaster.com
emi@enviromaster.com
4
ELECTRICAL SPECIFICATIONS
Indoor Unit V-Ph-Hz
Voltage Indoor Fan Motor Heater
Unit
FLA
MCA MOCP
Min Max RLA HP kW Amps
UNH09
UNH12
115-1-60 104 126 0.64 0.02
- - .64 0.8 15
0.75 6.50 7.14 8.9 15
208/230-1-60 197 240 0.34 0.02
- - 0.34 0.4 15
3.00 13.04 13.38 16.7 20
UNH24
115-1-60 104 126 1.20 0.08
- - 1.20 1.5 15
0.75 6.52 7.72 9.7 15
1.25 10.90 12.10 15.1 20
208/230-1-60 197 240 0.56 0.07
- - 0.56 0.7 15
3.00 13.04 13.60 17.0 20
5.00 21.74 22.30 27.9 30
Manufacturer reserves the right to change these specications at any time without incurring obligation.
EMI ENGINEERING SUBMITTAL UNH-T2H-T3H-T4H
Outdoor
Unit
Power Supply
V-1-60
Control*
V-1-60
Compressor Outdoor Fan Motor
Unit
FLA
MCA MOCP
Volts Min Max Qty RLA LRA Qty FLA Hp
T2H8800
208/230 197 240 24 2 5.4 36.0 1 1.8 0.33 12.6 14.0 15
T2H8400
208/230 197 240 24
1 5.4 36.0
1 1.8 0.33 16.0 18.2 25
1 8.8 54.0
T2H4400
208/230 197 240 24 2 8.8 54.0 1 1.8 0.33 19.4 21.6 30
T2H2400
208/230 197 240 24
1 4.3 27.0
1 1.8 0.33 14.9 17.1 25
1 8.8 54.0
T2H9800
208/230 197 240 24
1 3.4 23.0
1 1.8 0.33 10.6 12.0 15
1 5.4 36.0
T3H9990
208/230 197 240 24 3 3.4 23.0 1 1.8 0.33 12.0 12.9 15
T3H9920
208/230 197 240 24
2 3.4 23.0
1 1.8 0.33 12.9 14.0 15
1 4.3 27.0
T3H9980
208/230 197 240 24
2 3.4 23.0
1 1.8 0.33 14.0 15.4 20
1 5.4 36.0
T3H9940
208/230 197 240 24
2 3.4 23.0
1 1.8 0.33 17.4 19.6 25
1 8.8 54.0
T3H9220
208/230 197 240 24
1 3.4 23.0
1 1.8 0.33 13.8 14.9 15
2 4.3 27.0
T3H9280
208/230 197 240 24
1 3.4 23.0
1 1.8 0.33
14.9 16.3 20
1 4.3 27.0
1
5.4 36.0
T3H9240
208/230 197 240 24
1 3.4 23.0
1 1.8 0.33
18.3 20.5 25
1 4.3 27.0
1
8.8 54.0
T3H2280
208/230 197 240 24
2 4.3 27.0
1 1.8 0.33 15.8 17.2 20
1
5.4 36.0
Note: * - Control Voltage is supplied from the indoor unit. No separate supply required.