EMI ENGINEERING SUBMITTAL UNH-T2H-T3H-T4H
Model
Circuit
Cooling
Btuh (kW)
Heating
Btuh (kW)
Outdoor Indoor Air Handler
T2H8800 (2) UNH24
1 18,000 (5.3) 13,400 (3.9)
2 18,000 (5.3) 13,400 (3.9)
T2H8400 (2) UNH24
1 18,000 (5.3) 13,400 (3.9)
2 24,000 (7.0) 18,700 (5.5)
T2H4400 (2) UNH24
1 24,000 (7.0) 18,700 (5.5)
2 24,000 (7.0) 18,700 (5.5)
T2H2400
(1) UNH12
(1) UNH24
1 11,000 (3.2)
9,200
(2.7)
2 24,000 (7.0) 18,700 (5.5)
T2H9800
(1) UNH09
(1) UNH24
1
9,200 (2.7)
7,400 (2.2)
2
18,000 (5.3) 13,400 (3.9)
T3H9990 (3) UNH09
1
9,200 (2.7)
7,400 (2.2)
2
9,200 (2.7)
7,400 (2.2)
3
9,200 (2.7)
7,400 (2.2)
T3H9920
(2) UNH09
(1) UNH12
1 9,200 (2.7)
7,400 (2.2)
2 9,200 (2.7)
7,400 (2.2)
3 11,300 (3.3)
9,200
(2.7)
T3H9980
(2) UNH09
(1) UNH24
1 9,200 (2.7)
7,400 (2.2)
2 9,200 (2.7)
7,400 (2.2)
3 17,900 (5.2) 13,400 (3.9)
T3H9940
(2) UNH09
(1) UNH24
1 9,200 (2.7)
7,400 (2.2)
2 9,200 (2.7)
7,400 (2.2)
3 23,900 (7.0) 18,700 (5.5)
T3H9220
(1) UNH09
(2) UNH12
1 9,200 (2.7)
7,400 (2.2)
2 11,300 (3.3)
9,200
(2.7)
3 11,300 (3.3)
9,200
(2.7)
T3H9280
(1) UNH09
(1) UNH12
(1) UNH24
1 9,200 (2.7)
7,400 (2.2)
2 11,300 (3.3)
9,200
(2.7)
3 17,900 (5.2) 13,400 (3.9)
T3H9240
(1) UNH09
(1) UNH12
(1) UNH24
1 9,200 (2.7)
7,400 (2.2)
2 11,300 (3.3)
9,200
(2.7)
3 23,900 (7.0) 18,700 (5.5)
(Continued) UNH / T2H, T3H, or T4H SySTem
CapaCiTieS
Model Cooling Heating
Outdoor Indoor Air Handler
Btuh
(kW)
SEER SHR EER
Btuh
(kW)
HSPF COP
T3H9240 (1) UNH09, (1) UNH12, (1) UNH24 44500 (13.0) 13 0.69 11.7 35200 (10.3) 7.7 3.2
T3H2280 (2) UNH12, (1) UNH24 40500 (11.9) 13 0.76 11.8 31800 (9.3) 7.7 3.3
T3H2240 (2) UNH12, (1) UNH24 46500 (13.6) 13 0.68 11.7 37000 (10.8) 7.7 3.2
T3H2220 (3) UNH12 34000 (10.0) 13 0.72 11.7 27600 (8.1) 7.7 3.3
T4H9999 (4) UNH09 37200 (11.0) 13 0.8 11.9 29600 (8.7) 7.7 3.3
T4H9992 (3) UNH09, (1) UNH12 39000 (11.4) 13 0.77 11.8 31400 (9.2) 7.7 3.3
T4H9922 (2) UNH09, (2) UNH12 41000 (12.0) 13 0.76 11.8 33200 (9.7) 7.7 3.3
T4H9222 (1) UNH09, (3) UNH12 43000 (12.6) 13 0.72 11.6 35000 (10.3) 7.7 3.3
T4H2222 (4) UNH12 45000 (13.2) 13 0.72 11.7 36800 (10.8) 7.7 3.3
Circuit Designators: 9 = 9000 Btuh 2 = 12000 Btuh 8 = 18000 Btuh 4 = 24000 Btuh (ex. - 8400 consists of one 18000 Btuh compressor and one 24000 Btuh compressor)
UNH / T2H, T3H, or T4H CirCUiT performaNCe DaTa
Model
Circuit
Cooling
Btuh (kW)
Heating
Btuh (kW)
Outdoor Indoor Air Handler
T3H2280
(2) UNH12
(1) UNH24
1 11,300
(3.3)
9,200 (2.7)
2 11,300
(3.3)
9,200 (2.7)
3 17,900
(5.2)
13,400
(3.9)
T3H2240
(2) UNH12
(1) UNH24
1 11,300
(3.3)
9,200 (2.7)
2 11,300
(3.3)
9,200 (2.7)
3 23,900
(7.0)
18,700
(5.5)
T3H2220 (3) UNH12
1 11,300
(3.3)
9,200 (2.7)
2 11,300
(3.3)
9,200 (2.7)
3 11,300
(3.3)
9,200 (2.7)
T4H9999 (4) UNH09
1 9,300 (2.7) 7,400
(2.2)
2 9,300 (2.7) 7,400
(2.2)
3 9,300 (2.7) 7,400
(2.2)
4 9,300 (2.7) 7,400
(2.2)
T4H9992
(3) UNH09
(1) UNH12
1 9,300 (2.7) 7,400
(2.2)
2 9,300 (2.7) 7,400
(2.2)
3 9,300 (2.7) 7,400
(2.2)
4 11,200 (3.3) 9,200 (2.2)
T4H9922
(2) UNH09
(2) UNH12
1 9,300 (2.7) 7,400
(2.2)
2 9,300 (2.7) 7,400
(2.2)
3 11,200 (3.3) 9,200 (2.7)
4 11,200 (3.3) 9,200 (2.7)
T4H9222
(1) UNH09
(3) UNH12
1 9,300 (2.7) 7,400
(2.2)
2 11,200 (3.3) 9,200 (2.7)
3 11,200 (3.3) 9,200 (2.7)
4 11,200 (3.3) 9,200 (2.7)
T4H2222 (4) UNH12
1 11,200 (3.3) 9,200 (2.7)
2 11,200 (3.3) 9,200 (2.7)
3 11,200 (3.3) 9,200 (2.7)
4 11,200 (3.3) 9,200 (2.7)