EMI WLCA Air Conditioner User Manual


 
www.enviromaster.com
37
WLCA/WLHA High Wall Evaporator
WLCA/WLHA SYSTEM OPTIONS
NOTE: Due to EMI’s ongoing development programs, design and specications
may change without notice.
S1CA/S1HA
Side Discharge
WLCA/
WLHA
S2CA
Side Discharge
COOLING SYSTEMS WITH WALL UNITS
C o n d e n s e r Wall Unit Btuh SEER SHR EER
Ref.
S1CA9 WLHA09 9,000 13.0 .79 11.8
R22
S1CA2 WLHA12 12,000 13.0 .74 12. 9
R22
S1CA8 WLHA24 18,000 13.0 .78 13.0
R22
S1CA4 WLHA24 24,000 13.0 .70 12.5
R22
S1CA3 WLCA36 30,000 13.0 .72 12.6
R22
S1CA6 WLCA36 33,600 13.0 .69 12. 1
R22
HEAT PUMPS SYSTEM OPTIONS WITH WALL UNITS
Condenser Wall Unit
Cooling
Btuh
Heating
Btuh
SEER HSPF SHR EER COP
Ref.
S1HA9 WLHA09 9,000 8,200 13.0 7.7 .75 12.0 3.6
R22
S1HA2 WLHA12 12,000 10,200 13.0 7.7 .73 11.1 3.4
R22
S1HA8 WLHA24 18,000 16,400 13.0 7.7 .73 12.1 3.8
R22
S1HA4 WLHA24 23,000 20,600 13.0 7.7 .71 11.9 3.5
R22
COOLING SYSTEMS WITH S2CA SIDE DISCHARGE
Wall Unit (s) C o n d e n s e r Btuh SEER SHR EER Ref.
WLHA09 S2CA99 18,000 13 .80 11.9 R22
WLHA12 S2CA22 23,000 13 .72 12.4 R22
WLHA09+WLHA12 S2CA92 21,000 13 .72 12.0 R22