Emerson SST1000 Air Cleaner User Manual


 
13
OZONE REDUCTIONOZONE REDUCTION
OZONE REDUCTIONOZONE REDUCTION
OZONE REDUCTION
All electronic air cleaners typically produce a small
amount of ozone that is within established limits.
Some customers may notice an odor especially at
high altitudes or low air flow rates.
This power supply has a “hairpin” shaped jumper
wire labeled W1 (see Fig 24) that can be cut and
separated in case of such complaints. This will
cause the power supply to limit the maximum
operating power to a lower level.
OzOz
OzOz
Oz
one Rone R
one Rone R
one R
eduction Jeduction J
eduction Jeduction J
eduction J
umperumper
umperumper
umper
Figure 24
LINE
WHT/BRN BLK
W1
E3 E2
Cut and separate
Ozone Reduction
Jumper
Cabinet
Pre-Filters
Handle
Contact
Button
Contact
Button
Collecting Cells
INSTALLATIONINSTALLATION
INSTALLATIONINSTALLATION
INSTALLATION
1. Remove the two pre-filters from the package and
insert into cabinet tracks opposite the furnace. These
will be used to catch the larger particles that are in the
air stream before entering the collecting cell.
2. Insert the two collecting cells into the cabinet behind
the pre-filters. Be sure ionizing wires are directly
behind the pre-filters so the particles can be charged
as soon as the air leaves the pre-filters.
3. Remove cover plate on the power supply junction box
and remove the knockout needed to bring the wire to
the female receptacle.
4. Position receptacle with ground in the down position
as shown in Fig 17 (page 7) and pull wires through the
receptacle locator on the junction box. Snap the
receptacle into the hole until secure.
5. Connect ground wire from receptacle and ground wire
in kit to cabinet with rivet and washer as follows:
a) Place washer on rivet
b) Place terminal from ground wire on rivet
c) Place terminal from receptacle ground wire on
rivet
d) Insert rivet in hole in junction box and secure.
WIRINGWIRING
WIRINGWIRING
WIRING
5. For wiring installation (see page 7) and follow all
wiring instructions 7, 8 and 9.
6. Install the power pack (see page 7) instruction 11.
7. For operation (see page 8 – Operation).
ELECTRELECTR
ELECTRELECTR
ELECTR
ONIC ONIC
ONIC ONIC
ONIC
AIR CLEANER RETRAIR CLEANER RETR
AIR CLEANER RETRAIR CLEANER RETR
AIR CLEANER RETR
OFIT (AOFIT (A
OFIT (AOFIT (A
OFIT (A
CR) KITSCR) KITS
CR) KITSCR) KITS
CR) KITS