If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
10.Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connector supplied. (Figure 10).
11.Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 10). Securely connect the fan
motor black wire to the supply black (hot) wire
using wire connector supplied (Figure 10). After
connections have been made, turn leads upward
and carefully push leads into the outlet box.
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.
WARNING
!
OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
DOWNROD ASSEMBLY
NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.
Figure 9
THREADED
STUD (2)
HANGER
BRACKET
WHITE SUPPLY
(NEUTRAL)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
LISTED WIRE
CONNECTOR (3)
SUPPLY
GROUND WIRE
GREEN WIRE
(GROUND) FROM
HANGERBALL
BLACK FAN
WIRE
BLACK SUPPLY
(HOT)
WHITE
FAN WIRE
Figure 10
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
!
12. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket (Figure 10).
13. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 11).
14. Secure the ceiling cover in place by sliding lockwash-
ers over the threaded studs and installing the two
knurled knobs (supplied) (Figure 11). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling.
CEILING COVER
THREADED STUD
KNURLED KNOB
LOCKWASHERS (2)
Figure 11
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
WARNING
!
15. Mount blade flanges to fan blades using three
3/16-24 x 3/8” slotted washer head blade screws,
three plastic washers (Figure 12).
NOTE: Take care not to scratch fan housing when
installing blades.
NOTE: Remove and discard the four shipping
spacers and screws from the motor hub.
3/16-24 X 3/8" WASHER
HEAD BLADE SCREW (3)
PLASTIC WASHER (3)
FAN BLADE
BLADE
FLANGE
Figure 12