Emerson CF925BK00 Fan User Manual


 
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch wire
switch wire connections in the switch housing. connections in the switch housing.
CAUTION: Make sure main power is turned off.
3. Reversing switch in neutral position. 3. Make sure reversing switch position is all the way to one
side.
2. Fan sounds noisy. 1. Blades not attached to fan. 1. Attach blades to fan before operating.
2. Screws securing fan blade flanges to motor are 2. Check to make sure the screws which attach the fan
loose. flanges to the motor are tight.
3. Screws holding blades to flanges are loose. 3. Tighten screws securely.
4. Glass bowl loose. 4. Tighten the glass bowl securely.
3. Fan wobbles 1. Setscrew in motor coupling is loose. 1. Raise coupler cover and tighten the setscrew securely.
excessively. 2. Setscrew in hanger ball/downrod assembly is 2. Tighten the setscrew in the hanger ball/downrod assembly.
loose.
3. Screws securing fan blade flanges to motor are 3. Check to be sure screws which attach the fan blade
loose. flanges to the motor are tight.
4. Fan blade flanges not seated properly. 4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor. If flanges are
seated incorrectly, loosen the flange screws and retighten
according to the procedure in the section on "How to Put
Your Ceiling Fan Together".
5. Hanger bracket and/or ceiling outlet box is not 5. Tighten the hanger bracket screws to the outlet box, and/or
securely fastened. secure outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
1. Restore electrical power to the outlet box by turning
the electricity on at the main fuse box or circuit
breaker panel.
2. All fans are shipped from the factory with the
reversing switch positioned to circulate air
downward. If airflow is desired in opposite direction,
turn your fan off and wait for the blades to stop
turning, then slide the reversing switch to (located
at the top of the motor housing) opposite position,
and turn fan on again. The fan blades will turn in
the opposite direction and reverse the airflow.
3. Refer to the Owner’s Manual supplied with the
SR100 Fan/Light Control for operation of the fan
and light.
7
Using Your Ceiling Fan
Installing Glass Globe
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
1. Install three candelabra base bulbs in sockets.
2. Place the glass bowl into the opening in the light kit
plate, aligning the three flat areas on the top edge
of the glass with the three raised dimples on the
light kit plate and turn the glass bowl clockwise until
it stops (Figure 13).
NOTE: periodically check that the glass bowl is
seated fully clockwise in the light kit plate.
RAISED
DIMPLES
LIGHT KIT
PLATE
FLAT AREA
Figure 13