Emerson CF925BK00 Fan User Manual


 
1. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the clevis pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in step 5.
2. Loosen setscrew in motor coupling if necessary.
Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Align the clevis pin holes in the downrod
with the holes in the motor coupling. Install the
clevis pin and secure with the hairpin clip (Figure
2). The clevis pin must go through the holes in the
motor coupling and the holes in the downrod. Be
sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working
loose. Pull on the downrod to make sure the clevis
pin is properly installed.
3. While pulling up on the downrod, securely tighten
the setscrew in the motor coupling (Figure 3).
NOTE: The setscrew must be properly installed as
described above, or fan wobble could result.
SETSCREW
CLEVIS PIN
MOTOR
COUPLING
DOWNROD
HAIRPIN
CLIP
Figure 2
4. Make sure the grommet is properly installed in the
coupling cover then slide the coupler cover on the
downrod until it rests on the motor housing. Place
the ceiling cover over the downrod. Be sure both
the ceiling cover and the coupler cover are
oriented correctly (Figure 3).
5. Reinstall the hanger ball (Figure 4) on the downrod
as follows. Route the motor leads through the
downrod. Position the pin through the two holes in
the downrod and align the ball so the pin is captured
in the groove in the top of the hanger ball. Pull the
hanger ball up tight against the pin and securely
tighten the setscrew in the hanger ball. A loose
setscrew could create fan wobble.
6. The fan comes with blue, black and white leads
that are 80” long. Before installing fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.
7. Mount blade flanges to fan blades using three
3/16-24 x 5/16” slotted Phillips washer head blade
screws and three fiber blade washers (Figure 5).
PIN
SETSCREW
HANGER
BALL
DOWNROD
Figure 4
4
COUPLER
COVER
MOTOR
COUPLING
CLEVIS
PIN
SETSCREW
HAIRPIN
CLIP
CLEVIS
PIN
CEILING
COVER
Figure 3
PIN
SETSCREW
HANGER
BALL
DOWNROD
Figure 1
How to Put Your Ceiling Fan Together
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed (as shown in Figure 2) could
result in the fan falling.
WARNING
!
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.
WARNING
!