Emerson CF925BK00 Fan User Manual


 
1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description,
refer to exploded view illustration.
a. Fan motor assembly
b. One ceiling cover
c. Five fan blades
d. Five blade flanges
e. One hanger ball/downrod assembly
f. One hanger bracket
g. One glass globe
h. One SR100 fan/light control
i. One light kit plate
j. One adapter plate
k. One coupler cover
l. One loose parts bag containing:
1. Sixteen 3/16-24 x 5/16” slotted Phillips
washer head blade screws
2. Sixteen Fiber blade washers
3. Eleven 1/4-20 x 3/8” Phillips oval head
flange screws
4. Three wire connectors
5. Two 3/4" threaded studs
6. Two lockwashers
7. Two knurled knobs
8. One clevis pin
9. One hairpin clip
10. One 3/16” hex wrench
11. Three 3/16-24 nuts
This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder
One 1/4” blade screwdriver One wire stripper
Three wire connectors (supplied)
One 3/16” hex wrench (supplied)
MATERIALS
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
size:
3
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is
completed, place a check mark in the box. This will insure that all steps have been
completed and will be helpful in finding your place should you be interrupted.
NOTE: Place the parts from the loose parts bags
in a small container to keep them from being lost.
If any parts are missing, contact your local
retailer or catalog outlet for replacement before
proceeding.
2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper
foam pad with the top of the motor facing up.
The upper foam pad serves as a holder for the fan
during the first stages of assembly.
BLADE
FLANGES
GLASS
BOWL
ADAPTER PLATE
FAN
ASSEMBLY
COUPLER
COVER
CEILING
COVER
FAN BLADES
LIGHT KIT
PLATE
HANGER
BRACKET
HANGER BALL/
DOWNROD
ASSEMBLY
LOOSE
PARTS
BAG
SR100
FAN/LIGHT
CONTROL
HI OFF
LOWMED
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Before assembly your ceiling fan, refer to section on
proper method of wiring your fan (page 6). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.
WARNING
!
Do not install or use fan if any part is damaged or
missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.
WARNING
!
WARNING
!