To avoid possible fire or shock, make
sure that the electrical wires are
completely inside the outlet box and
not pinched between the ceiling
canopy and the ceiling.
!
WARNING
SW102 FAN/LIGHT WALL
CONTROL (SUPPLIED)
BLACK
BLACK
WHITE
RED
BLACK
WHITE
HANGER BALL
GREEN WIRE (GROUND)
FROM HANGER BALL AND
HANGER BRACKET
TWO-CONDUCTOR
CABLE (WITH
GROUND)
BLACK
(HOT)
WHITE
GROUND
TO
120-
VOLT
SUPPLY
WHITE
BLUE
WHITE
BLUE
FAN OFF
LOW
MED
HI
LIGHT
Figure 11
3. Push the wires and connectors up into
the outlet box while inserting the
receiver fully into the hanger bracket.
Position the antenna wire on top of the
receiver.
4. Screw the two 1-1/4” threaded studs
(supplied) into the tapped holes in the
hanger bracket (Figure 10).
5. Lift the ceiling canopy up to the
threaded studs and turn until the studs
protrude through the holes in the ceiling
canopy (Figure 12).
6. Secure the ceiling canopy in place by
sliding lockwashers (supplied) over the
threaded studs and installing the two
knurled knobs (supplied) (Figure 12).
Tighten the knurled knobs securely
until the ceiling canopy fits snugly
against the ceiling.
LOCKWASHER
(2)
KNURLED
KNOB (2)
CEILING
CANOPY
1-1/4"
THREADED
STUD (2)
Figure 12
BLACK WIRE
BLUE WIRE
FITTER
ADAPTER
PLATE
HOUSING
DOWNLIGHT
ASSEMBLY
WHITE WIRES
REMOVE ONE M4 x 8mm
OVAL HEAD SCREW .
LOOSEN THE TWO
REMAINING SCREWS.
KEYHOLE SLOTS
Figure 13
7. Engage the connectors of the housing
downlight assembly with the connectors
of the motor assembly (black to blue:
white to white) (Figure 13).
8. Remove and retain one of the three
M4 x 8mm oval head screws from
the fitter adapter plate. Loosen the
remaining two screws.
10
U.L. Model No.: CF725
BP7369 Vienne 12/7/08 5:21 PM Page 10