Emerson CF690ORB00 Fan User Manual


 
1. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in step 5.
2. Unscrew the setscrew (Figure 2) until it clears the
inside of the motor coupling. Then separate,
untwist and unkink the three 80” motor leads.
Route the motor lead wires through the downrod.
Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 2). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Be sure to
push the straight leg of the hairpin clip through the
hole near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on
the downrod to make sure the clevis pin is properly
installed.
3. Tighten the setscrew (Figure 2) securely while
pulling up on the downrod.
NOTE: The setscrew must be properly installed as
described above, or fan wobble could result.
4. Make sure the grommet is properly installed in the
coupling cover, then slide the coupling cover on the
downrod until it rests on the motor housing. Place
the ceiling cover over the downrod. Be sure that
the ceiling cover and the coupling cover are both
oriented correctly (Figure 3).
5. Reinstall the hanger ball (Figure 4) on the downrod
as follows. Route the three 80” motor leads through
the hanger ball. Position the pin through the two
holes in the downrod and align the hanger ball so
the pin is captured in the groove in the top of the
hanger ball. Pull the hanger ball up tight against the
pin and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.
6. The fan comes with blue, black and white leads
that are 80-inches long. Before installing the fan,
measure up approximately 6 to 9-inches above top
of hanger ball/downrod assembly. Cut off excess
leads and strip back insulation 1/2-inch from end of
leads.
7. Mount blade flanges to fan blades (rib line
facing up) using three M5 x 6 washer head screws
(Figure 5).
4
How to Put Your Ceiling Fan Together
PIN
SETSCREW
HANGER
BALL
DOWNROD
Figure 1
CEILING
COVER
COUPLING
COVER
DOWNROD
Figure 3
HAIRPIN
CLIP
DOWNROD
CLEVIS
PIN
MOTOR
COUPLING
HAIRPIN
CLIP
SETSCREW
CLEVIS PIN
MOTOR COUPLING
SETSCREW
Figure 2
CEILING COVER
DOWNROD
PIN
SETSCREW
HANGER
BALL
Figure 4
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely tight-
ened. Failure to verify that the pin and setscrew are
properly installed (as shown in Figure 2) could result
in the fan falling.
WARNING
!
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are proper-
ly installed could result in the fan falling.
WARNING
!