6
1
2
3
4
5
6
Cleaning the motor filter
(The motor filter should be cleaned approximately every three
months, or when required for more frequent use).
1 Pull dustbag upward and remove the motor protection fil-
ter.
2 Rinse the filter under tap water and allow 24 hours to dry.
3 Put the filter back into the cleaner and close the cover.
Filter reference number: EF 1.
Replacing the micro exhaust filter
(The exhaust filter should be replaced approximately every 4
months).
4 Open the filter grill to remove the exhaust filter.
5 Remove the filter unit.
6 Take the filter out of the grill and insert a new one.
5 Put the filter set back into the cleaner.
6 Close the filter cover.
Note: Do not use cleaning agents and avoid touching the delicate
filter surface.
Z45xx_ifu_2.qxp 2005.04.27. 10:59 Page 6