Electrolux CF921GES00 Fan User Manual


 
4
1. The receiver must be programmed within 2 minutes of restoring
electricity to the fan. Program the receiver code by pushing and
holding down the remote control OFF button for 3-5 seconds.
The ceiling fan lights will blink when the receiver has completed
programming.
2. If programming fails, shut off and turn on the electricity at the
wall switch to reset the receiver. Repeat Step 1 above.
3. If programming continues to fail, change the remote code and
repeat Steps 1 and 2 as necessary until the fan successfully
completes the programming procedure.
NOTE: Fan installation must be completed, including the
installation of the fan blades, before testing the remote control.
4. Your SR600 Fan/Light remote control has full control of your
fan speed, air flow direction and light intensity.
ETL Model No.: CF921
* For additional installation review full instructions on
page 12.
Programming and Operation of Remote Control (pages 11 and 12)
1. Connect the green grounding lead from the hanger ball and the
green grounding lead from the hanger bracket to the grounding
conductor of supply (this may be a bare wire or wire with green
colored insulation). Securely connect wires with wire
connectors supplied.
NOTE: If you are using an Emerson Light Fixture with your fan,
see Light Fixture Owner’s Manual for wiring.
2. Securely connect the fan motor white wire to the supply white
(neutral) wire using wire connector supplied. Securely connect
the fan motor black wire to the supply black (hot) wire using
wire connector supplied.
3. After connections have been made, turn leads upward and
carefully push leads into the outlet box, with the white and green
leads on one side of the outlet box and the black on the other
side of the outlet box.
NOTE: CEILING COVER
OMITTED FOR CLARITY.
GROUND
WIRE
LISTED WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
WHITE SUPPLY
(NEUTRAL)
BLACK SUPPLY (HOT)
BLACK
FAN WIRE
WHITE FAN WIRE
Wiring Ceiling Fan (page 10)
1. Separate the grounded white neutral and green wires on one
side of the outlet box from the ungrounded black wire on the
other side of the outlet box
2. Insert the grounded green and white wires into one side of the
outlet box, and the ungrounded black wire into the other side of
the outlet box.
3. Screw the two threaded studs into the tapped holes in the
hanger bracket.
4. Install the ceiling cover onto the hanger bracket. using the studs,
lock washers and knurled nuts supplied.
Installation of Ceiling Cover (page 10)
EMERSON QUICK START GUIDE