Elation Professional Power Wash 575E Indoor Furnishings User Manual


 
Elation Lighting www.elationlighting.com 21
minutes after having switched off (lamp too hot). The message will
appear on the display if the lamp doesn’t ignite within 20 seconds.
The fixture will store this command and automatically ignite the lamp
after 5 minutes.
IG E
When igniting the lamp, the electronic ballast will examine whether the
lamp ignited or not. If the lamp does not ignite within 20 seconds, the
igniting sequence is broken off. Now approx. 2 minutes are waited,
until a renewed ignition attempt is started automatically. After the 3rd
unsuccessful ignition attempt the sequence is completely stopped
and the display reads "IG E" (Ignition error).
LAER
As soon as the lamp ignited correctly, the lamp current is constantly
supervised by the system. If an interruption steps on (covers opened
or lamp damaged), the power is switched off immediately. The display
reads "LAER" (lamps error). Please switch off the power supply and
solve the possible problem.
After the error "IG E" respectively "LAER" it is not anymore possible the start
the lamp via Shutter = 255. Nevertheless if a renewed ignition attempt is
desired, first run a Reset (at the Spot or over DMX). Afterwards you can try again
to ignite the lamp.
OTMP
This error message informs you that the fixture was overheating and
that the relay switches off the lamp. Pleas look for possible reasons
(fan faulty, air in/outlets blocked or very dirty, lamp broken or very old,
too high ambient temperature. Switch off the power supply and solve
the possible problem.
RsER
This message informs you that one of the fixture function wasn’t able
to do its reset correct (magnetic sensor, stepping motor, driver on the
PCB, cables, etc.). Repair the defect and start the fixture again.