In the case of the ELAR 216 Panel ™, which is up to a nine channel fixture, you should set
the starting DMX address of the first unit to 1, the second unit to 10 (9 + 1), the third unit to
19 (9 + 10), and so on.
Note: During start-up the ELAR 216 Panel ™ will automatically detect whether a DMX data
signal is being received or not. If a DMX data signal is being received, the display will show
"A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a DMX
signal the display will flash "A.XXX" (XXX representing the actual DMX address).
If your fixture is connected to a DMX controller and the display is flashing (not receiving a
DMX signal), please check the following:
- The 3-pin or 5-pin XLR plug (cable with DMX signal from controller) may not be
connected or is not inserted completely into the DMX input jack.
- The DMX controller is switched off or defective.
- The DMX cable from the controller merging with included IP Rated Cable adapter is
not connected securely
- The DMX cable or connector is defective.
- A DMX terminator has been inserted into the last fixture in your DMX chain.